Estimate continuous runtime or daily energy and days of backup. Appliance wattages and compressor duty cycles are editable planning estimates. Enable JavaScript to use this calculator. Run everything at once: runtime hours = (capacity in Wh × efficiency) ÷ total running watts. Daily energy and days of backup: daily Wh = Σ (running watts × quantity × hours per day × duty cycle); backup days = (capacity in Wh × efficiency) ÷ daily Wh. Efficiency defaults to 85% and is adjustable from 70% to 95%. Duty cycle is an editable estimate of the share of time an appliance draws its entered wattage. Appliance presets are editable typical estimates, not measured readings. Refrigerator duty cycle defaults to a 40% planning estimate only; actual cycling depends on the appliance, temperature, settings, and conditions, so adjust it for your scenario. Duty cycle is used in daily energy and sizing calculations. Run-everything-at-once mode does not use hours per day or duty cycle. The 85% efficiency default is an estimate. Start-up surge multipliers are estimates and are not substitutes for appliance or station specifications. Actual runtime varies with conversion losses, temperature, battery age, output type, and operating conditions. These calculations are for planning and do not guarantee performance. These examples use the same calculation functions as the interactive tool. Results in daily mode are rounded to the nearest hour. No. They are editable typical estimates. Use the appliance label or manual for a more accurate input. No. It is a planning estimate; actual runtime can vary with cycling, conversion losses, temperature, battery condition, and operating conditions.How this works
Assumptions and limitations
Frequently asked questions
Calculation examples
Mode Inputs Expected result Run at once 1,000 Wh; 85%; 72 W 11 hr 48 min Run at once 1,000 Wh; 85%; 1,000 W 0 hr 51 min Run at once 500 Wh; 85%; 100 W 4 hr 15 min Run at once 1,000 Wh; 70%; 100 W 7 hr 00 min Run at once 2,000 Wh; 95%; 500 W 3 hr 48 min Run at once 500 Wh; 85%; 1 W 425 hr 0 min Daily energy 1,000 Wh; 85%; 72 W × 1 × 4 h × 100% 2 days 23 hr Daily energy 1,000 Wh; 85%; 150 W × 1 × 8 h × 40% 1 day 19 hr Daily energy 1,000 Wh; 85%; 60 W × 2 × 5 h × 50% 2 days 20 hr Daily energy 500 Wh; 85%; 100 W × 1 × 2 h × 100% 2 days 3 hr Daily energy 2,000 Wh; 85%; 200 W × 2 × 6 h × 50% 1 day 10 hr Input check 0 Wh capacity or 0 Wh/day Clear validation message; no result Are appliance presets exact?
Does this predict real-world runtime?